WE_CU control unit

This control unit is used for connection into the WIS access system. Its construction makes it designated for installation into the lower ceiling with an ability to connect two reading units. For the dragON technology it supports connection of reader heads with the RS 485 interface. It is equipped with a controlling microprocessor x51 and it is able to connect up to 8 reader heads WEGA of the KRBox type or up to 8 APERIO HUBs. It also contains new diagnostic LED diodes which check the functions of the functional departments of the reading unit. When it comes to operation, it can work in an online mode, with the ability to switch offline in case communication problems appear.

Versions of the WE_CU control unit

WE_CU
WIST02CU WE_CU control unit
Plastic cover
Technical parameters 
Dimensions 190 mm x 140 mm x 70 mm
Weight 400 g
Voltage/Power supply 9-14V DC
Max. consumption 150 mA pri 13V8
Data memory SRAM 128 kB backed up by internal battery
Galvanic separation Only bus RS 485
Communication interface RS 485
 Number of all or nothing relays For dragON technology needed to add product Input/Output module for the WE_CU dragON system
Max. switched current 6 A DC, LED diagnostics of relay conduct
Inputs On WEGA reader head - door opening sensor
Number of reading heads 1 to 8
Interface of connected reading heads WIEGAND, RS 232
Display No
Range of working temperatures -25, +50ºC
IP coverage IP 56 - plastic cover

Inputs/Outputs

The control unit contains predefined inputs and outputs. Their function is apparent from the connector description J4. The active state of the inputs is given by the configuration of the control unit, and configuration can only be done from the configuration utility. While using the outputs (relay contacts) and controlling the charge of an inductive character the contacts must be connected correctly to the control unit. The positive pole of the controlled charge always must be connected to the NO or NC contacts. While controlling the electromagnetic locks the safety diode must be connected in reverse direction. .

Partners

3M
LH logo
Legic logo
LH erb

References

ZSR logo
Viena logo
Vegum logo
Union logo
TRW logo
Trimleader logo
Trens logo
TC Contact logo
Tatrapet logo
TAMI logo
SVPS
Skoda logo
SWEP logo
Swedwood logo
SUZA logo
Stuerm logo
Sony logo
Socialna poistovna logo
SPF logo
SZRB logo
Slovalco logo
Posta logo
Slovmatic logo
Slavia logo
Skippi logo
SI Medical logo
Schule logo
Schneider logo
Samsung logo
Rona logo
Raven logo
Rajo logo
Lumen logo
Profinetwork logo
Prefa logo
PMZA logo
PB logo
Plus7 logo
Plastika logo
OTP logo
NTS logo
NCHZ logo
Nera logo
Neoprot logo
Neografia logo
Nemocnica PP logo
NLC logo
Nafta logo
Movys logo
MZV logo
Petrzalka logo
MU BA Stare mesto logo
Mediaprint logo
Med-art logo
Martimex logo
MAR SK logo
Lind logo
Levmilk logo
Legia logo
Lear logo
KSUTN logo
Konstrukta logo
Knott logo
KFL logo
Kelcom logo
Katolicka univerzita logo
Johnson Controls logo
Johns Manville logo
JMT logo
J.P.Software logo
Javys logo
InsData logo
INA logo
IMPA logo
Chirana logo
Chemosvit logo
Chemolak logo
HP logo
Heineken logo
Hartman-Rico logo
Gude logo
Grandcom logo
GG logo
Gemsys logo
Gefco logo
Gastrosyst logo
Formica logo
Faurecia logo
Eurocast logo
Esox logo
EMM logo
Enel logo
Emerson logo
Eltek logo
Eissman logo
Edscha logo
Duslo logo
Dr.Oetker logo
Primabanka logo
Telekom logo
Detska fakultna nemocnica logo
DeMiclen logo
Datacentrum logo
Daňové riaditeľstvo SR logo
ČSOB logo
ČSOB Leasing logo
Cromwell logo
Colne riaditelstvo logo
CDCP logo
Brose logo
Bekeart logo
Autoalles logo
Branson logo
CD profil logo
AWT logo
Avex logo
Aspel logo
Aquacity Poprad logo
AFE logo
Abonus logo
Akademia ozbrojenych sil logo
Aliter logo
Pepsi logo
Cargo logo

Site visit statistics

  • Unique Visitors: 91019
  • Since: 11/04/2020 - 15:14